Series VM
Their solid structure and the filtering media, that can be regenerated several times, makes them particularly suitable in industrial processes providing high loads of dust. During assembly special care is given to the inclusion of the filtering pack in order to make it integral with the frame to avoid possible dust passage.
For more information: see the data sheet
-
Frame: galvanized steel
-
Protective mesh: on both sides - electrowelded galvanized steel wire
-
Filtering septum: layers of metal mesh in aluminium cuspidated braiding
-
Efficiency class CEN EN 779: G2
-
Eurovent class: EU 2
-
Arrestance Ashrae 52.1.1992 Am: 65%-70%-75% (depending on the thickness)
-
Available thickness (mm): 10-12-18-20-23-30-35-40-45-48
-
Maximum operating temperature: 200°C